Stud Bolt Dimensions & Size Chart

Manufacturer, Supplier & Exporter of Stud Bolts and Double-End Studs following DIN, ASME/ANSI, BS and IS Standards in Mumbai, India.

Stud bolt is a type of headless fastener with either one or two nuts at the ends or tapped flange which is used to connect equipment that requires pressure retention. Since the stud is responsible for the clamping load of a flange or pressure joint, it is very important to ensure that the dimensions of the stud are accurate, such as the diameter, pitch and the length of the thread engagement and overall length. Unifit Metalloys Inc. manufactures studs with utmost precision in accordance with the DIN, ASME/ANSI, BS and IS standards. All studs we supply are tested before they are sent out on nominal diameter, thread engagement and length to ensure they fit the first time they are installed onsite. 

Unifit Metalloys Inc. has been producing Stud Bolts since 2014 and is certified to ISO 9001:2015 Quality Management System. This reference page contains information about stud bolt dimensions, stud bolt size chart, double-end stud dimensions, thread specifications, tolerances, weight details and applicable standards for engineers, purchasing departments and customers. 

The best price of Stud Bolts and Double-End Studs according to your need for a specific Stud Bolt Dimension Standard can be obtained by contacting Unifit Metalloys for your needs regarding the size, material, standard and number of Stud Bolts required.

What Do Stud Bolt Dimensions Include?

A stud is not equal to a diameter. Stud Bolt Dimensions: These are all the sizes that are used to determine whether the stud will fit, hold and function in a joint.

  • Nominal Diameter (D) – size of a stud as specified, M20 or 3/4".
  • Pitch (P) – the distance between the crests of the thread, mm for metric series of studs and threads per inch (TPI) for inch series of studs.
  • The outside diameter of the thread, the diameter at the bottom of the thread and the diameter on the centre of the thread profile are called Major, Minor and Pitch Diameter.
  • B1 (Thread Engagement Length) – The length of the thread that is engaged in the flange or equipment body (varies by standard: DIN 938 = 1×D, DIN 939 = 1.25×D, DIN 940 = 2.5×D) depending on the base material being tapped).
  • B2 (Nut-End Thread Length) – length of threaded end of the double end stud at the nut end, which is sized to fit a nut and washer.
  • Overall length (L) – the total length from end to end (excluding the tap end, as per DIN 938 convention) for stud bolts.
  • Full Threaded or Continuous Thread Studs – how many threads are threaded (b) for these types of studs.

These are all given by the Stud Bolt Dimension Standard, and a stud made by one manufacturer and a nut by another will fit. Standardisation is all about that, and that's why Stud Bolt Dimension charts have been developed.

Types of Stud Bolts by Dimension Style

Type Typical Standard Typical Use

Full-threaded / continuous-thread stud

DIN 976-1 / ASME B18.31.2

Equipment assembly and general fastening

Double-end / tap-end stud

DIN 938 / DIN 939 / DIN 940

Tapped-hole and pressure-joint applications

Flange bolting stud

ASME B18.31.2

Flange bolting

Reduced-shank stud

DIN 2510 series

High-temperature/high-pressure equipment

Stud Bolt Dimension Standards Comparison

Stud Bolt Dimension standards are issued by international and national organizations and are specific to a particular stud type, a thread system and a metric or inch measurement system. Unifit Metalloys manufactures the following:

Standard Description Thread Engagement Measurement System

DIN 835

Double-end stud bolt

— (general form)

Metric

DIN 938

Double-end stud, engagement = 1×D

1×Diameter

Metric

DIN 939

Double-end stud, engagement = 1.25×D

1.25×Diameter

Metric

DIN 940

Double-end stud, engagement = 2.5×D

2.5×Diameter

Metric

DIN 949-1

Double-end stud, engagement = 2×D

2×Diameter

Metric

DIN 949-2

Double-end stud, engagement = 2.5×D

2.5×Diameter

Metric

DIN 975 / DIN 976

Threaded rod / plain end stud

Full length

Inch / Metric

DIN 2509

Double-end stud

—

Metric

DIN 2510 (L/Z/K/ZU/KU/GP/GQ/GR/GS/HP)

Reduced-shank double-end stud

Varies by form

Metric

BS 1769

Double-end threaded stud

—

½"–2"

BS 2693

Stud bolt

—

Inch

BS 3692

Stud bolt

—

Metric

BS 4439

Double-end stud, engagement = 1.5×D

1.5×Diameter

Metric

IS 1862

Stud bolt

—

Metric

IS 13178

Clamping stud

—

Metric

ASME/ANSI B18.31.2

Continuous thread stud

Full length

Inch

ASME/ANSI B16.5

Chamfered-end stud for flange bolting

—

Inch

ASME B18.2.1

Stud bolt (general reference)

—

Inch

All of these Stud Bolt Dimension Standards are available from our stockyard, in material types such as stainless steel, alloy steel, carbon steel, duplex steel and nickel alloys.

Why Engagement Length Differs (DIN 835 vs 938 vs 939 vs 940 vs 949)

The diameter and pitch are the same for DIN 938, DIN 939, and DIN 940 studs, but the length of thread that the stud engages into the tapped hole is different — 1×D, 1.25×D and 2.5×D respectively. When the base material being tapped is softer or weaker than the material of the studs (cast iron or aluminium bodies, for instance), then a longer engagement is needed to distribute the clamping load across more flanks of the thread. The same logic applies to DIN 949-1 and 949-2, which are based on the same engagement lengths of 2xD and 2.5xD, for certain classes of equipment, and DIN 835 establishes the double-end stud form that these engagement-length standards are based upon. One of the most frequently occurring failure modes in service is the result of the wrong engagement length being selected for the base material.

Send Your Enquiry

Stud Bolt Dimension Chart (Double-End Studs)

Stud bolts are available in either full threaded or double-end type. Double-end studs are also divided by the amount of thread that is engaged into the tapped hole, which is DIN 938 (1×D), DIN 939 (1.25×D) and DIN 940 (2.5×D). There are three different Stud Bolt Dimension Standards used for the same fastener as it relates to the material being tapped; the longer the engagement the more load that is supported, for a softer material.

Callouts—D (nominal diameter), P (pitch), B1 (thread engagement at the tap end), B2 (thread length at the nut end), L (overall length).

DIN 938 double end stud bolt dimension diagram B1 and B2 thread engagement

DIN 938 / DIN 939 / DIN 940 — Side-by-Side Comparison (mm)

Diameter (D) Pitch DIN 938 B1 (1×D) DIN 939 B1 (1.25×D) DIN 940 B1 (2.5×D) B2, L ≤ 200 B2, L = 125–200 B2, L ≥ 200

M10

1.50

10

12.5

25

26

32

45

M16

2.00

16

20

40

38

44

57

M20

2.50

20

25

50

46

52

65

M24

3.00

24

30

60

54

60

73

M30

3.50

30

37.5

75

66

72

85

M36

4.00

36

45

90

78

84

97

Please request up to DIN 938, DIN 939 and DIN 940 Stud Bolt Dimension charts.

Full Threaded Stud Bolt Dimension Chart

Counselling: Combined inch series and metric equivalents for cross reference:

Nominal Diameter (Inch) Metric Equivalent Pitch Diameter Max Pitch Diameter Min Major Diameter Max Major Diameter Min Minor Diameter Min
1/2" M12 0.499" 0.488" 0.499" 0.488" 0.404"
3/4" M20 0.748" 0.735" 0.748" 0.735" 0.626"
1" M24 0.998" 0.983" 0.998" 0.983" 0.845"
1.1/4" M30 1.248" 1.233" 1.248" 1.233" 1.095"
1.1/2" M36 1.498" 1.483" 1.498" 1.483" 1.344"
2" M48 1.998" 1.983" 1.998" 1.983" 1.844"

The metric equivalents are not 1:1 conversions but are used as a good reference size for cross comparison. See FAQ below for more details.

Stud Bolt Weight Chart

The weight of a stud is a function of its density, cross-sectional area and length, and is therefore dependent on both diameter and length.

By Length (kg per piece)

Length (mm) 1/2" 3/4" 1" 1.1/4" 1.1/2"

100

0.085 kg

0.196 kg

0.353 kg

0.570 kg

0.841 kg

150

0.125 kg

0.290 kg

0.521 kg

0.842 kg

1.242 kg

200

0.165 kg

0.383 kg

0.689 kg

1.113 kg

1.642 kg

250

0.205 kg

0.477 kg

0.857 kg

1.385 kg

2.043 kg

300

0.246 kg

0.570 kg

1.025 kg

1.656 kg

2.443 kg

By Diameter — kg per 1000 pcs (fixed length, for bulk quoting)

Diameter Weight per 1000 pcs (approx., 100mm length)

1/2"

85 kg

3/4"

196 kg

1"

353 kg

1.1/4"

570 kg

1.1/2"

841 kg

Depending on the order which is placed, weight is often given per 1000 pieces at a fixed length, as opposed to per running metre — our sales team will clarify either on request.

Stud Bolt Dimension Tolerances

In addition to the Stud Bolt Dimension Standard, each dimension also has a tolerance range for length, since no manufacturing process can deliver a precise dimension.

Length Range Tolerance

Up to 12"

± 0.052" (± 1.32 mm)

Over 12" to 18"

± 0.125" (± 3.18 mm)

Over 18"

± 0.250" (± 6.35 mm)

Unifit Metalloys measure the dimensions of their studs for packing within these tolerances, and they are able to provide inspection reports on request, in addition to mill test certificates.

Stud Bolt Thread Types and Pitch

There are different dimension standards for stud bolts depending on the thread system:

  • The thread pitch is specified in mm as per ASME B13M / DIN. The most common usage is coarse thread (default), when higher preload accuracy is required it is fine thread, e.g. critical flange joints.
  • The pitch is given in terms of Unified Threads (UNC / UNF) per ASME B1.1. UNC is the coarse series, UNF the fine series.
Size Threads per Inch (TPI) Pitch (mm) Tap Drill Size (mm)

1/2"-13

13

1.954

11.15

3/4"-10

10

2.540

17.00

1"-8

8

3.175

22.85

1.1/2"-6

6

4.233

34.70

Stud Bolt Grades vs Stud Bolt Dimensions

Often asked question: Does a higher grade stud equate to a different sized stud? No. This does not indicate size of stud but instead indicates the tensile and yield strength of the material of which the stud is composed, e.g., B7, B7M, B8, B8M. Stud Bolt dimensions are the same for M20 stud bolts in Grade B7 and Grade B8M, the only difference is the amount of load that they can each safely bear. First the applicable Stud Bolt Dimension Standard (by diameter, pitch and length) should be selected, then the grade according to the strength and service conditions required.

Stud Bolt Materials & Grades (ASTM A193)

Grade Material Type

B7

Chromium-molybdenum alloy steel

B7M

Chromium-molybdenum alloy steel (sour service)

B8 / B8A

Austenitic stainless steel (AISI 304)

B8M / B8Mcl2

Austenitic stainless steel (AISI 316)

B16

Chromium-molybdenum-vanadium alloy steel (high-temperature)

Grade changes strength, not Stud Bolt Dimensions — an M20 stud in B7 and an M20 stud in B8M share the same dimensions and differ only in load and corrosion capability.

Stud Bolt Load Capacity & Torque Reference

There are other factors to consider besides nominal diameter when selecting stud bolt load capacity. The allowable load is influenced by material grade, tensile area, thread geometry, temperature, joint configuration and required design safety factor. Diameter is not the only factor that should be used to choose assembly torque. There are many factors which influence the torque to achieve the preload relationship, such as friction at the threads and bearing surfaces, lubrication, surface finish and the type of torque specified.

Therefore, the project specification should specify the required flange preload or the flange tightening procedure, as well as the method for calculating flange torque, if the flange joint is critical.

Factor Effect on Load / Torque Selection

Nominal diameter

Influences tensile stress area and available load capacity

Thread pitch

Influences thread geometry and tightening behaviour

Material grade

Determines mechanical properties

Lubrication

Changes friction and therefore torque-to-preload relationship

Surface condition

Influences friction and tightening consistency

Joint design

Determines required preload and clamping load

Operating temperature

Can affect material strength and joint behaviour

Unifit provides studs in all Stainless Steel,Alloy Steel,Duplex Steel,Super Duplex Steel, and Nickel Alloy

How to Select the Right Stud Bolt Dimension

  1. Size the diameter of the bolt hole or flange rating of your design.
  2. Verify the Stud Bolt Dimension Standard as it might be different, depending on the specification (ASME B16.5, DIN, BS, IS, etc.) the same nominal size might have two different tolerances per specification.
  3. The engagement length standard that is used (DIN 938, 939 or 940) depends on the base material being tapped — softer materials require longer engagement.
  4. Verify convention of length: under DIN 938, length does NOT include the tap end (b1).
  5. Check the thread pitch – both coarse and fine are available at the same diameter for stud bolts.
  6. Check and confirm the material grade for temperature, pressure and corrosion conditions — grade and Stud Bolt Dimensions are independent.

Applications of Stud Bolts

Correct Stud Bolt Dimensions are essential when under pressure, vibration or load. Unifit Metalloys provides stud bolts that meet these standards in each of the following:

  • Refineries
  • Oil and Gas Industry
  • Power Generation
  • Pharmaceutical Equipment
  • Pulp and Paper Industry

Frequently Asked Questions 

How long is an M20 stud bolt?

While some dimensions are common for all M20 stud bolts, others are determined by the governing standard and configuration. For instance, with an M20 DIN 938 stud, the length of thread engagement of the metal end is about 20 mm (1×D) and about 25 mm (1.25×D) for DIN 939. Always order based on the standard and length from the engineering drawing.

Why is there a difference between DIN 938, DIN 939 and DIN 940 stud bolts?

There are different lengths of engagement for the metal-end thread in the DIN 938, DIN 939 and DIN 940. They have nominal engagement references of about 1×D, 1.25×D and 2.5×D. You should use the appropriate standard based on the equipment specification, stud design and mating material and not always take the longest engagement grade.

What is the length of a stud bolt?

The length of the stud bolt is to be read in compliance with the relevant standard as the length of the studs may be different in different configurations. The metal-end thread length can be considered separately for DIN tap-end studs. When ordering, always double check the length designation as indicated in the appropriate standard or purchase drawing.

What's the difference between a stud bolt and a threaded rod?

A stud bolt is prepared according to a certain configuration and dimension specification, and the threaded rod is generally used continuously as a thread rod that is cut to a specific length. There is a current DIN 976-1 standard for metric stud bolts which should not be assumed to be generic threaded rod.

What is the standard for stud bolts for flange bolting?

ASME B18.31.2 is the directly relevant stud standard for studs that are used for flange bolting and are primarily used with flange applications covered by ASME B16.5 (flange series flange bolting). The flange standard is ASME B16.5 itself and should be checked in conjunction with the applicable stud and material requirements.

What is the difference in size between grades of stud bolts?

The upgrade of the material grade does not automatically cause the diameter and the thread geometry to be changed to the specified nominal value or the same tolerance requirements, provided that the same stud standard and the same thread form and the same tolerance requirements are used. The main properties of the material and the mechanical properties like strength and service capacity are primarily determined by the grade. The entire purchase specification should specify not only size but also the grade of material.

Get Stud Bolts in Your Required Dimension & Standard

Unifit Metalloys Inc. produces stud bolt and double end studs in accordance to DIN, ASME/ANSI, BS & IS Stud Bolt Dimensions, in Stainless Steel,Alloy Steel, Duplex Steel, Super Duplex Steel, and Nickel Alloy.

Contact us for a quote, or view our full range of Fasteners.

Get a Quote →